CBSFK - NICKEL CADMIUM SEALED CELL BATTERY

Product Identification

Product ID:NICKEL CADMIUM SEALED CELL BATTERY
MSDS Date:10/03/1994
FSC:6140
NIIN:01-027-8706
MSDS Number: CBSFK

Responsible Party
SAFT AMERICA INC, POWER SOURCES DIV
711 INDUSTRIAL BLVD
VALDOSTA, GA 31603
US

Emergency Phone: 800-424-9300(CHEMTREC)

Info Phone: 912-247-2331/912-245-2880 FAX

Cage: 09052

Contractor
SAFT AMERICA INC.
1886 VALDOSTA, GA 31602 US

Telephone: 912-247-2331

Cage: 09052

Ingredients

CADMIUM (SARA 313) (CERCLA) (TOTAL AS CADMIUM, INGREDS

CAS: 7440-43-9

RTECS: EU9800000

Fraction By Weight: <17%

OSHA PEL 0.2 MG/M3 DUST; Z-2

ACGIH TLV: 0.01 MG/M3 DUST;9596

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


CADMIUM HYDROXIDE

CAS: 21041-95-2

Fraction By Weight: SEE #1%

OSHA PEL 0.05 MG CD/M3

ACGIH TLV: 0.05 MG CD/M3


CADMIUM OXIDE (SARA 302/313) (CERCLA)

CAS: 1306-19-0

RTECS: EV1925000

Fraction By Weight: SEE #1%

OSHA PEL 0.2 MG (CD)/M3 DUST

ACGIH TLV: 0.01 MG(CD)/M3; 9596


NICKEL (SARA 313) (CERCLA) (TOTAL AS NICKEL, INGREDS 5,6)

CAS: 7440-02-0

RTECS: QR5950000

Fraction By Weight: 19%

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3; 9596


NICKEL HYDROXIDE (SARA 313) (CERCLA)

CAS: 12054-48-7

RTECS: QR7040000

Fraction By Weight: SEE #4%

OSHA PEL 1 MG(NI)/M3

ACGIH TLV: 0.1 MG(NI)/M3; 9596

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


NICKEL OXIDE

CAS: 1313-99-1

RTECS: QR8400000

Fraction By Weight: SEE #4%

OSHA PEL 1 MG/M3 AS NI

ACGIH TLV: 1 MG/M3 AS NI


POTASSIUM HYDROXIDE (CERCLA)

CAS: 1310-58-3

RTECS: TT2100000

Fraction By Weight: 85 - 90%

OSHA PEL C 2 MG/M3

ACGIH TLV: C 2 MG/M3; 9596

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


COBALT HYDROXIDE AS COBALT METAL

CAS: 1307-86-4

RTECS: GG0904000

Fraction By Weight: 1%

OSHA PEL 0.05 MG/M3(COBALT)

ACGIH TLV: 0.1 MG/M3

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE:ELECTRO SOLN IN BATT EXTREMELY
CORROSIVE TO EYE TISSUES. MAY RESULT IN PERMANENT BLINDNESS.
CONTACT W/NIO MAY CAUSE MINOR IRRITATION. SKIN:CONTACT W/
ELECTROLYTE SOLN MAY CAUSE SERIOUS BURNS TO TI SSUE. CONTACT W/
NICKEL CMPDS MAY CAUSE SKIN SENSITIZATION, RESULTS IN CHRONIC
ECZEMA/ NICKEL ITCH. INGETSION: TISSUE DAMAGE TO THROAT AREA/ GI/
RESPIRATORY TRACT. NI CMPD NAU, GI (SUPP)
Explanation of Carcinogenicity:PER MSDS:CARCINOGENICITY:NIOSH
RECOMMENDS THAT NICKEL & CADMIUM BE TREATED AS OCCUPATIONAL
CARCINOGENS.
Effects of Overexposure:PERM BLINDNESS.MINOR IRRIT,SERIOUS BURNS TO
SKIN TISSUES.SKIN SENSIZATION,CHRONIC ECZEMA,NICKEL ITCH.DMG TO
THROAT AREA & GI/RESP TRACTS,NAU,INTESTINAL DISORDERS.MILD IRRIT OF
NASAL MUCOUS MEMB TO DMG OF LUNG TISSUES PROPER.DRY
THROAT,COUGH,HEAD,VOMIT,CHEST PAINS,CHILLS,PULM EDEMA,DIFFI
BREATH,PROSTRATION,KIDNEY DMG.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYE:FLUSH W/PLENTY OF WATER @LEAST 15MINS IF ABUSE CAUSES SAF
VENT TO ACTIVATE.GET IMMED MED ATTN.SKIN:REMOVE CONTAM CLOTH.FLUSH
W/PLENTY OF WATER @LEAST 15MINS.WASH W/SOAP/WATER.INGEST:DO NOT
INDUCE VOMIT.DILUTE BY GIVING WATER.IF AVAILABLE GIVE SEVERAL
GLASSES OF MILK.GET IMMED MED ATTN.DO NOT GIVE ANYTHING BY MOUTH IF
UNCONSC.INHAL:REMOVE TO FRESH AIR.GIVE OXY/ART RESP.GET IMMED MED
ATTN.

Fire Fighting

Flash Point:PRODUCT NOT PROV
Autoignition Temp:Autoignition Temp Text:NP
Lower Limits:NP
Upper Limits:NP
Extinguishing Media:CO2, SAND.
Fire Fighting Procedures:USE SELF-CONTAINED BREATH APPARATUS TO AVOID
BREATH TOXIC FUMES.WEAR PROTECTIVE CLOTH/EQPMT TO PREVENT POTENTIAL
BODY CONTACT W/ELECTRO SOLN/MIX OF WATER/SOLN.
Unusual Fire/Explosion Hazard:ELECTRO SOLN CORRO TO ALL HUMAN
TISSUES;RXS VIOLENTLY W/MANY ORG CHEM ESPECIALLY
NITROCARBONS/CHLOROCARBONS.ELECTRO SOLN RXS W/ZN,AL,SN,ACTIVE
METALS (SUPPLEME)

Accidental Release

Spill Release Procedures:ELECTROLYTE SPILLS:FLUSH W/WATER & NEUTRALIZE
W/DILUTE CITRIC ACID.
Neutralizing Agent:ELECTROLYETE SOLN NEUTRALIZED W/DILUTE CITRIC ACID.

Handling

Handling and Storage Precautions:CELL/BATT CONTRUCTED FROM THEM MAY BE
HIGHLY CHARGED;ARE CAPABLE OF HIGH ENERGY DISCHARGE.DO NOT SHORT
CIRCUIT-MAY CAUSE BURNS.DO NOT BREAK OPEN CELL.
Other Precautions:CARE SHOULD BE TAKEN TO HNDL CELLS PROPERLY TO AVOID
SHORTING/MISUSE THAT WILL RESULT IN RAPID UNCONTROLLED
ELECTRICAL/CHEM/HEAT ENERGY RELEASE.DO NOT ALLOW EXPO FLAME OR
SPARK TO COME NEAR CELLS.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR IF CELL
BROKEN OPEN DURING FIRE TO MAINTAIN EXPSOURE LEVELS BELOW TWA FOR
CADMIUM & NICKEL COMPOUDNS.
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:WATER-INSOL NON-PERM GLOVES(SYN RUBB).
Eye Protection:SPLASH GOGGLES OR FACE SHIELD.
Other Protective Equipment:DO NOT USE LEATHER OR WOOL GLOVES.RUBBER
APRON OR EQUIFALENT IF EXPO TO ELECTROLYTE SOLN LIKELY.
Work Hygienic Practices:WASH CONTAMIN CLOTH BEF REUSE.
Supplemental Safety and Health
FIRE/EXPLO HAZ:CD FUMES RELEASED WHEN BATT SUBJ TO HIGH TEMP.DON'T
BREATH FIRE FUMES. HEALTH HAZ:DISORDERS.INHAL:CD/NI CMPDS VARY:MILD
NASAL MUC MEMB IRRIT TO LUNG TISSUE DMG PROPER.CDO CAUSE DRY THRO
AT,COUGH,HEAD,VOMIT,CHEST PAIN,CHILLS.CHRONIC OVEREXPO PULM
EDEMA,DIFFI BREATH,PROSTRATION,KIDNEY DMG.

Chemical Properties

HCC:Z5
Boiling Pt:B.P. Text:NA
Melt/Freeze Pt:M.P/F.P Text:NA
Decomp Temp:Decomp Text:NP
Vapor Pres:NA
Vapor Density:NA
Spec Gravity:1.170-1.250 ELC
pH:NP
Viscosity:NP
Evaporation Rate & Reference:NOT DETERMINED.
Solubility in Water:ELECTRO COMPLETELY
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:NP
Corrosion Rate:NP

Stability

ALUMINUM, ZINC, TIN & OTHER ACTIVE METALS, ACID, CHLORINATED & AROMATIC
HYDROCARBONS, NITROCARBONS, HALOCARBONS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NICKEL OXIDE, CADMIUM, CADMIUM OXIDE,
POTASSIUM HYDROXIDE.

Disposal

Waste Disposal Methods:STORAGE BATT HAZ WASTE UNDER RCRA.MAY BE
RETURNED TO SAFT FOR RECYCLING.BATT IS TCLP TOXIC.BATT/ELECTRO SOLN
CORR.IF NOT RECYCLED MSUT BE DISPO OF IAW ALL FED/STATE/LOC REGS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.